首页> 外文期刊>Microelectronics & Reliability >Interface microstructure effects in Au thermosonic ball bonding contacts by high reliability wire materials
【24h】

Interface microstructure effects in Au thermosonic ball bonding contacts by high reliability wire materials

机译:高可靠性导线材料对金热超声球焊触点的界面微观结构影响

获取原文
获取原文并翻译 | 示例

摘要

Palladium-doped and (Cu, Pt)-doped high reliability gold wires were used to form wire bond interconnects on aluminum IC metallization. By isothermal annealing of wire bond samples the formation of intermetallic Au-Al phases was stimulated. SEM/EBSD investigations of the phase regions exhibited significantly slower isothermal growth rates compared to a reference gold wire. Correlated TEM, STEM-EDXS and nanobeam diffraction analyses revealed that Pd is preferentially incorporated into the AugAl_3 intermetallic forming a new stable phase but additionally can obviously form a new Pd-rich ternary intermetallic. In comparison, Cu dopants are also accumulated into a new Al-Au-Cu phase while Pt is rather found agglomerating within grain boundaries and interfaces. These results suggest a diffusion barrier model that allows discussing how wire doping can affect the bond contact microstructure, thus increasing the lifetime of bond contacts.
机译:掺杂钯和(Cu,Pt)掺杂的高可靠性金线用于在铝IC金属上形成引线键合互连。通过线键合样品的等温退火,促进了金属间Au-Al相的形成。与参考金线相比,相区的SEM / EBSD研究显示出等温生长速度明显慢。相关的TEM,STEM-EDXS和纳米束衍射分析表明,Pd优先结合到AugAl_3金属间化合物中,形成新的稳定相,但显然可以形成新的富Pd三元金属间化合物。相比之下,Cu掺杂剂也累积到新的Al-Au-Cu相中,而Pt则在晶界和界面内聚集。这些结果提出了一种扩散阻挡层模型,该模型可以讨论导线掺杂如何影响键合触点的微观结构,从而增加键合触点的寿命。

著录项

  • 来源
    《Microelectronics & Reliability》 |2014年第10期|2000-2005|共6页
  • 作者单位

    Fraunhofer Institute for Mechanics of Materials IWM, Center for Applied Microstructure Diagnostics, Walter-Huelse-Strasse 1, 06120 Halle, Germany;

    Fraunhofer Institute for Mechanics of Materials IWM, Center for Applied Microstructure Diagnostics, Walter-Huelse-Strasse 1, 06120 Halle, Germany;

    Fraunhofer Institute for Mechanics of Materials IWM, Center for Applied Microstructure Diagnostics, Walter-Huelse-Strasse 1, 06120 Halle, Germany;

    Fraunhofer Institute for Mechanics of Materials IWM, Center for Applied Microstructure Diagnostics, Walter-Huelse-Strasse 1, 06120 Halle, Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Wire bonding; Intermetallic compounds; Doping; Microstructure analysis; TEM; Reliability;

    机译:引线键合;金属间化合物;掺杂显微组织分析;TEM;可靠性;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号