首页> 外文期刊>Microelectronics & Reliability >Fast power cycling protocols implemented in an automated test bench dedicated to IGBT module ageing
【24h】

Fast power cycling protocols implemented in an automated test bench dedicated to IGBT module ageing

机译:在专用于IGBT模块老化的自动测试台中实现了快速功率循环协议

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents fast test protocols for ageing IGBT modules in power cycling conditions, and a monitoring device that tracks the on-state voltage V_(CE) and junction temperature T_J of IGBTs during ageing test operations. This device is implemented in an ageing test bench described in previous papers, but which has since been modified to perform fast power cycling tests. The fast test protocols described here use the thermal variations imposed on IGBT modules by a test bench operating under Pulse Width Modulation conditions. This test bench reaches the maximal values of power cycling frequencies attainable with a given module packaging in order to optimize test duration. The measurement device monitors V_(CE) throughout the ageing test that is needed to detect possible degradations of wire bonds and/or emitter metallization. This requires identifying small V_(CE) variations (a few dozen mV). In addition, the thermal swing amplitude of power cycling must be adjusted to achieve a given ageing protocol. This requires measuring junction temperature evolution on a power cycle, which is carried out by means of V_(CE) measurement at a low current level (100 mA). Experimental results demonstrate the flexibility of this test bench with respect to various power cycling conditions, as well as the feasibility of the proposed on-line monitoring methods.
机译:本文介绍了在功率循环条件下老化IGBT模块的快速测试协议,以及一种监视设备,该设备可跟踪老化测试操作期间IGBT的导通电压V_(CE)和结温T_J。该器件在以前的论文中描述的老化测试台中实现,但此后经过修改以执行快速功率循环测试。这里描述的快速测试协议使用在脉冲宽度调制条件下运行的测试台施加在IGBT模块上的热变化。该测试台达到了给定模块封装所能达到的功率循环频率的最大值,以优化测试持续时间。在整个老化测试过程中,测量设备会监控V_(CE),以检测引线键合和/或发射极金属化的可能退化。这需要识别小的V_(CE)变化(几十mV)。另外,必须调整功率循环的热摆幅以实现给定的老化协议。这就需要在电源周期上测量结温的变化,这是通过在低电流水平(100 mA)下进行V_(CE)测量来进行的。实验结果证明了该测试台在各种功率循环条件下的灵活性,以及​​所提出的在线监测方法的可行性。

著录项

  • 来源
    《Microelectronics & Reliability》 |2015年第1期|81-92|共12页
  • 作者单位

    Universite Montpellier 2, Institut d'Electronique et Systemes, CC079, Place E. Bataillon, 34095 Montpellier cedex 5, France;

    Universite Montpellier 2, Institut d'Electronique et Systemes, CC079, Place E. Bataillon, 34095 Montpellier cedex 5, France;

    Universite Montpellier 2, Institut d'Electronique et Systemes, CC079, Place E. Bataillon, 34095 Montpellier cedex 5, France;

    Universite Montpellier 2, Institut d'Electronique et Systemes, CC079, Place E. Bataillon, 34095 Montpellier cedex 5, France;

    Universite Montpellier 2, Institut d'Electronique et Systemes, CC079, Place E. Bataillon, 34095 Montpellier cedex 5, France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Bond wire ageing; IGBT modules; Power cycling; Real-time monitoring;

    机译:键合线老化;IGBT模块电源循环;实时监控;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号