The multifunctional operation of photovoltaic (PV) inverters consists in providing ancillary services to the power grid, such as reactive power injection, harmonic current compensation and frequency regulation. However, it is necessary to quantify the effect of those extra activities on the PV inverter life consumption. This work analyzes the life consumption of a single phase multifunctional inverter during harmonic current load compensation. The mission profile of harmonic current, irradiance and temperature are considered by the lifetime model to obtain a more realistic estimation. Therefore, the power losses and thermal stress were evaluated on the semiconductors devices. In addition, rainflow method, Bayerers model and Palmgrem-Miners rules are used in the methodology. The results show that life consumption is correlated to the harmonic order, phase angle and harmonic amplitude. In addition, when the harmonic phase angle is equal to 180°, the life consumption can be lower than a conventional inverter in 9.5%. On the other hand, when the phase angle is 0°, the converter life consumption can increase in 15.2%.
机译:光伏(PV)逆变器的多功能运行包括为电网提供辅助服务,例如无功功率注入,谐波电流补偿和频率调节。但是,有必要量化这些额外活动对光伏逆变器寿命消耗的影响。这项工作分析了谐波电流负载补偿期间单相多功能逆变器的寿命消耗。寿命模型考虑了谐波电流,辐照度和温度的任务曲线,以获得更现实的估计。因此,在半导体器件上评估了功率损耗和热应力。此外,该方法还使用了雨流法,Bayerers模型和Palmgrem-Miners规则。结果表明,寿命消耗与谐波次数,相角和谐波幅度有关。另外,当谐波相角等于180°时,寿命消耗可比传统逆变器低9.5%。另一方面,当相角为0°时,转换器寿命消耗可增加15.2%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号