首页> 外文期刊>Mechanical systems and signal processing >Development of cylindrical-type finger force measuring system using force sensors and its characteristics evaluation
【24h】

Development of cylindrical-type finger force measuring system using force sensors and its characteristics evaluation

机译:利用力传感器的圆柱型手指力测量系统的开发及其性能评估

获取原文
获取原文并翻译 | 示例

摘要

Some patients cannot use their hands because of the paralysis of their fingers. Their fingers can recover with rehabilitative training, and the extent of rehabilitation can be judged by grasping a cylindrical-object with their fingers. At present, the cylindrical object used in hospitals is only a plastic cylinder, which cannot measure grasping force of the fingers. Therefore, doctors must judge the extent of rehabilitation by watching patients' fingers as they grasp the plastic cylinder. In this paper, the development of two cylindrical-type finger force measuring systems with four force sensors for left hand and right hand were developed. The developed finger force measuring system can measure the grasping force of patients' each finger (forefinger, middle finger, ring finger and little finger), and the measured results could be used to judge the rehabilitation extent of a finger patient. The grasping force tests of men and women were performed using the developed cylindrical-type finger force measuring systems. The tests confirm that the average finger forces of right hand and left hand for men were about 194 N and 179 N, and for women, 108 N and 95 N.
机译:一些患者由于手指麻痹而无法使用手。他们的手指可以通过康复训练恢复,并且可以通过用手指抓住圆柱物体来判断康复程度。目前,医院中使用的圆柱形物体仅仅是塑料圆柱体,无法测量手​​指的抓握力。因此,医生必须在病人抓住塑料筒时观察他们的手指来判断康复的程度。本文开发了两个带有四个左右手力传感器的圆柱型手指力测量系统。发达的手指力测量系统可以测量患者每个手指(食指,中指,无名指和小指)的抓握力,测量结果可用于判断手指患者的康复程度。使用开发的圆柱型手指力测量系统进行了男女的抓握力测试。测试证实,男性的右手和左手的平均手指力分别为194 N和179 N,女性为108 N和95N。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号