首页> 外文期刊>Meat Science >Optical measurements of pH in meat
【24h】

Optical measurements of pH in meat

机译:肉中pH值的光学测量

获取原文
获取原文并翻译 | 示例
       

摘要

The pH changes occurring in a carcass during the first 24 h after slaughter are important for the quality of the final meat or meat products. Protein denaturation will occur if pH falls to too low a level or if a relatively low pH sets in at a time after slaughter where the carcass temperature is still high. This will result in meat with poor water holding capacity and in extreme cases in meat that is PSE. pH is measured electrochemically using either glass or solid state (IS-FET) electrodes. However, electrochemically based methods are slow to use and do not offer good precision on unhomogenized meat. In this work it has been investigated whether pH can be measured spectroscopically in reflectance using the visual and near infrared spectral regions. On a limited number of pig meat samples (46 longissimus dorsi and 46 semimembranosus muscles) correlations of 0.85 have been achieved using the fast spec- troscopic techniques opposed to glass electrode measurements done in duplicate. The prediction errors for the spectroscopic tech- niques are found to be comparable to the precision of the reference method.
机译:屠宰后最初24小时内,occurring体中发生的pH值变化对于最终肉类或肉制品的质量非常重要。如果pH下降到太低的水平,或者屠宰后的屠体温度仍然很高,则pH会降低,则会发生蛋白质变性。这将导致肉的持水能力差,在极端情况下会导致PSE肉。使用玻璃或固态(IS-FET)电极电化学测量pH值。然而,基于电化学的方法使用缓慢并且不能在未均质的肉上提供良好的精度。在这项工作中,已经研究了是否可以使用可见光和近红外光谱区域以光谱法测量pH值。在有限数量的猪肉样品(46条背最长肌和46条半膜肌)上,使用快速光谱技术与一式两份进行玻璃电极测量相反,已经实现了0.85的相关性。光谱技术的预测误差被发现与参考方法的精度相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号