Two methods are proposed for determining the procedural error ΔT based on a comparison of the ratio and difference of the radiation signals picked up by a sensor from a primary standard and an object. Those methods, theoretical and experimental, require knowledge of the sensor conversion parameter. Both methods are shown to be correct and to give the same results. Tungsten and platinum are used as samples to show the relations the principal quantities that define the photoemission temperature measurements. These relations allow the optimum conditions to be chosen for measurement in a given temperature interval, taking into account the object and the sensor parameters.
机译:提出了两种方法,用于基于传感器从主要标准和物体拾取的辐射信号的比率和差值的比较来确定过程误差ΔT。这些方法,无论是理论方法还是实验方法,都需要了解传感器转换参数。两种方法都被证明是正确的,并且给出了相同的结果。钨和铂用作样品,以显示定义光电发射温度测量值的主要量之间的关系。这些关系允许在考虑到物体和传感器参数的情况下,在给定的温度间隔内选择最佳条件进行测量。