首页> 外文期刊>Measurement techniques >CHARACTERISTICS OF THE LONG-TERM INSTABILITY OF THE NEW-GENERATION HYDROGEN FREQUENCY AND TIME STANDARDS
【24h】

CHARACTERISTICS OF THE LONG-TERM INSTABILITY OF THE NEW-GENERATION HYDROGEN FREQUENCY AND TIME STANDARDS

机译:新一代氢气频率和时间标准的长期不稳定性的特征

获取原文
获取原文并翻译 | 示例
       

摘要

The latest changes in the algorithms for the formation of the International Atomic Time (TAI) scale are reported in terms of estimating the weights of the clocks involved in the formation of TAI. The characteristics of the long-term instability of new-generation hydrogen frequency and time standards from the State Primary Standard of time and frequency units and national time scale, GET 1-2018, were studied. The study was based on the results of processing the frequency difference with respect to TAI. It is confirmed that presently, new-generation hydrogen standards of frequency and time show significantly less long-term instability compared with similar and other quantum frequency standards.
机译:在估算Tai的形成时钟的重量方面,报告了用于形成国际原子时间(TAI)规模的算法的最新变化。研究了新一代氢气频率和时间标准的长期不稳定性的特点,从状态和频率单位和国家时间尺度获得1-2018。该研究基于处理与TAI的频率差的结果。证实,目前,与相似和其他量子频率标准相比,频率和时间的新一代氢标准显示出明显较少的长期不稳定。