Establishing the Cause of Fouling in a Direct Drainage-Type Cooling Water System

机译:确定直接排水式冷却水系统中的结垢原因

获取原文
获取原文并翻译 | 示例

摘要

The silt brought into the cooling water system is the main cause of the fouling. To avoid drawing in silt, the intake should be raised up or kept far enough away from silt deposition areas to en sure that the fluid velocity is slower than silt start-up velocity. Silt taken in by the cooling water should be monitored during power plant operation and silt should be removed before it reaches the plant.
机译:进入冷却水系统的淤泥是结垢的主要原因。为避免吸入淤泥,应提高进水口或使其远离淤泥沉积区域,以确保流体速度慢于淤泥启动速度。在电厂运行期间,应监控冷却水吸收的淤泥,并应在淤泥到达电厂之前清除淤泥。