Impressed current cathodic protection was installed on the coated piles of a jetty. The anodes were placed within galvanized steel support tubes that were welded to the piles. The anodes were isolated from the ends of the tubes, but a small portion of the anodes extended from each tube. After about a year, most of the support tubes had corroded and broken because of severe splash zone corrosion and the formation of hypochlorous acid (HOCI) from anodic reactions. Proper installation of anodes would have prevented this failure.
机译:外加电流阴极保护装置安装在码头的涂层桩上。阳极放置在镀锌钢支撑管中,该支撑管焊接到桩上。阳极与管的末端隔离,但一小部分阳极从每个管延伸。大约一年后,由于严重的飞溅区腐蚀以及阳极反应形成的次氯酸(HOCI),大多数支撑管已腐蚀并折断。正确安装阳极可以防止这种故障。