首页> 外文期刊>Materials Evaluation >Nondestructive Inspection of Piper PA25 Forward Spar Fittings
【24h】

Nondestructive Inspection of Piper PA25 Forward Spar Fittings

机译:Piper PA25前梁配件的无损检查

获取原文
获取原文并翻译 | 示例
       

摘要

The Federal Aviation Administration's (FAA's) Aging Aircraft NDI Validation Center (AANC) at Sandia National Laboratories applied two nondestructive inspection (NDI) techniques to inspect a forward spar fuselage attachment fitting. The techniques used were based on radiography and ultrasonic test methods. The combination of these techniques did reveal material thinning of two spar fittings from Piper PA25 aircraft. However, crack detection near a notch design feature could not be performed. Based on the results of these experiments, an ultrasonic test procedure was subsequently developed for the material thinning. The procedure has since been incorporated by the FAA into a revision of Airworthiness Directive 93-21-12.
机译:桑迪亚国家实验室的美国联邦航空管理局(FAA)老化飞机NDI验证中心(AANC)应用了两种非破坏性检查(NDI)技术来检查前梁机身的附件。所使用的技术基于射线照相和超声测试方法。这些技术的结合确实揭示了Piper PA25飞机的两个翼梁配件的材料变薄。但是,无法在缺口设计特征附近执行裂纹检测。基于这些实验的结果,随后开发了用于材料变薄的超声测试程序。此后,该程序已被FAA纳入对适航性指令93-21-12的修订中。

著录项

  • 来源
    《Materials Evaluation》 |1995年第7期|p.795-796|共2页
  • 作者

    David G. Moore;

  • 作者单位
  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 工程材料学;
  • 关键词

  • 入库时间 2022-08-18 00:57:33

相似文献