首页> 外文期刊>Materials Evaluation >Fluorescent Penetrant Inspection System Performance Test Using Known Defect Standards
【24h】

Fluorescent Penetrant Inspection System Performance Test Using Known Defect Standards

机译:使用已知缺陷标准的荧光渗透检测系统性能测试

获取原文
获取原文并翻译 | 示例

摘要

Penetrant inspection facilities should be informed of and be required to: 1. qualify (calibrate) all Tarn panels immediately after purchasing to confirm the number and actual sizes of the star burst/linear indications, and not use the drawing sizes for the periodic degradation check. 2. compare the Tarn panels indications during the System Performance Test against those obtained during the initial calibration. 3. not compare Tarn panel against (working vs. master) Tarn panel since no two panels are alike; rather to compare the Tam panel against its respective initial calibration sizes. 4. demonstrate repeatability of the same number of indications found during the initial Tarn panel calibration regardless of the penetrant sensitivity level during the periodic System Performance Test. 5. not use Tarn panels for the monthly sensitivity test for comparing used with unused penetrant materials.
机译:渗透检测设施应被告知并被要求:1.购买后立即对所有塔恩板进行鉴定(校准),以确认星爆/线性指示的数量和实际尺寸,并且不得将图纸尺寸用于定期降级检查。 2.将系统性能测试期间的Tarn面板指示与初始校准期间获得的指示进行比较。 3.不要将Tarn面板与Tarn面板进行比较(因为没有两个面板是相同的);而不是将Tam面板与其各自的初始校准尺寸进行比较。 4.展示出在塔恩(Tarn)面板初始校准期间发现的相同数量指示的可重复性,而与定期系统性能测试期间的渗透剂灵敏度水平无关。 5.请勿将塔恩面板用于每月灵敏度测试,以与未使用的渗透剂进行比较。