首页> 外文期刊>Magnetic Resonance in Medicine >Quantitative cerebral blood flow in dynamic susceptibility contrast MRI using total cerebral flow from phase contrast magnetic resonance angiography
【24h】

Quantitative cerebral blood flow in dynamic susceptibility contrast MRI using total cerebral flow from phase contrast magnetic resonance angiography

机译:动态磁化率对比MRI中的定量脑血流量,使用相衬磁共振血管造影术的总脑流量

获取原文
获取原文并翻译 | 示例
           

摘要

Dynamic susceptibility contrast magnetic resonance imaging during bolus injection of gadolinium contrast agent is commonly used to investigate cerebral hemodynamics. The large majority of clinical applications of dynamic susceptibility contrast magnetic resonance imaging to date have reported relative cerebral blood flow values because of dependence of the result on the accuracy of determining the arterial input function, the robustness of the singular value decomposition algorithm, and others. We propose a calibration approach that directly measures the total (i.e., whole brain) cerebral blood flow in individual subjects using phase contrast magnetic resonance angiography. The method was applied to data from 11 patients with intracranial pathology. The sum of squares variance about the mean (uncorrected: white matter = 105.6, gray matter = 472.2; corrected: white matter = 34.1, gray matter = 99.8) after correction was significantly lower for white matter (P = 0.045) and for gray matter (P = 0.011). However, the mean gray and white matter cerebral blood flow in the contralateral hemisphere were not significantly altered by the correction. The proposed phase contrast magnetic resonance angiography calibration technique appears to be one of the most direct correction schemes available for dynamic susceptibility contrast magnetic resonance imaging cerebral blood flow values and can be performed rapidly, requiring only a few minutes of additional scan time. Magn Reson Med, 2011. © 2011 Wiley-Liss, Inc.
机译:推注injection造影剂期间的动态磁化率对比磁共振成像通常用于研究脑血流动力学。迄今为止,由于敏感性取决于确定动脉输入功能的准确性,奇异值分解算法的鲁棒性等因素,动态磁化率对比磁共振成像的大多数临床应用都报告了相对的脑血流值。我们提出了一种校准方法,该方法使用相衬磁共振血管造影术直接测量个体受试者的总(即全脑)脑血流量。该方法应用于11例颅内病理患者的数据。校正后,均值的平方方差总和(未校正:白质= 105.6,灰质= 472.2;校正后:白质= 34.1,灰质= 99.8)对于白质和灰质而言显着较低(P = 0.045) (P = 0.011)。但是,对侧半球的平均灰色和白色物质脑血流量并未因校正而明显改变。提议的相衬磁共振血管造影校准技术似乎是可用于动态磁化率对比磁共振成像脑血流值的最直接的校正方案之一,并且可以快速执行,仅需要几分钟的额外扫描时间。 Magn Reson Med,2011年。©2011 Wiley-Liss,Inc.。

著录项

  • 来源
    《Magnetic Resonance in Medicine》 |2011年第1期|p.57-66|共10页
  • 作者单位

    Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland, United States;

    Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland, United States|F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, United States;

    |Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland, United States|F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, United States;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Dynamic Susceptibility Contrast MRI (DSC-MRI); Phase contrast MRA; total cerebral blood flow; calibration; quantitative MRI;

    机译:动态磁化率MRI(DSC-MRI);相差MRA;总脑血流量;校正;定量MRI;