It becomes necessary for reinforcement concrete columns under axial load at any way that they are capable to of inelastic response without appreciably losing load-carrying capacity. One of the ideal ways to ensure such ductility in columns is by specifying the amount, spacing and the configuration of transverse reinforcement in critical regions of columns. This study had been conducted to investigate description of some parameters affecting the performance of UHSC columns under combined axial load and lateral force. This result is provided that ductility is affected largely by the level of axial load applied to the columns. Therefore, when the level of axial load is above 50 percent of column axial load capacity and concrete compressive strength is approximately 100 MPa, amount of transverse reinforcement is required over 30 percent larger than specified in the seismic provisions of ACI 318-05 code for ductile behavior.
机译:在轴向载荷下以任何方式使其具有非弹性响应而又不会明显损失其承载能力的钢筋混凝土柱,变得很有必要。确保柱子具有这种延展性的理想方法之一是指定柱子关键区域中横向钢筋的数量,间距和配置。进行这项研究是为了研究在轴向载荷和侧向力共同作用下影响UHSC柱性能的一些参数的描述。得出的结果是,延展性很大程度上受到施加在柱子上的轴向载荷水平的影响。因此,当轴向载荷水平大于柱轴向载荷能力的50%,且混凝土抗压强度约为100 MPa时,要求横向钢筋的数量要比ACI 318-05延性规范中规定的抗震规定大30%以上行为。