Field investigations were conducted to identify the relationship between leakage rate and pressure in selected areas of the water distribution system of the Holy City of Makkah, Saudi Arabia. Noise correlators were used to detect leaks in areas where the water leakage exceeded 20% of the total water supplied. The leakage rate was found to be related to pressure raised to the nth power. The value of n was found to be 0.50 for the network of asbestos-cement pipes and 1.16 for the network of mixed pipes. Considering the age of the network, the leakage rate was found to be linearly related to the age of the network and related to pressure raised to the 1.10 power. About 63.15% of the leaks were found to be at the property connections. The rest were either in the service lines or at the junction of the service lines with the property connections. The galvanized iron property connections were found to be highly corroded, with circular holes and/or longitudinal corrosion cracks.
机译:进行了现场调查,以查明沙特阿拉伯麦加圣城配水系统某些区域的泄漏率与压力之间的关系。噪声相关器用于检测漏水量超过供水总量20%的区域的漏水情况。发现泄漏率与升至n次方的压力有关。发现石棉水泥管网的n值为0.50,混合管网的n值为1.16。考虑到网络的寿命,发现泄漏率与网络的寿命以及升至1.10功率的压力呈线性关系。发现大约63.15%的泄漏发生在物业连接处。其余的位于服务线中或服务线与属性连接的交界处。镀锌的铁质连接件被发现高度腐蚀,带有圆形孔和/或纵向腐蚀裂纹。