An experimental investigation has been carried out to examine heat-transfer characteristics of an axisymmetric, underexpanded, sonic jet impinging on a flat plate. The ratio of nozzle-exit pressure to the ambient pressure, that is, underexpansion ratio ranges from 1.5 to 3.5, and the distance from the nozzle exit to the plate is adjusted from 0.5 to 20.0 nozzle-exit diameters. Detailed measurements of the recovery factor and the surface pressure on the flat plate have been achieved. The results showed that the recovery factor obtained in the present study have distributions that are different from those for low-velocity jets. It has been found that the recovery factor at the stagnation point varies from 0.35 up to over 1.25 for the highest underexpansion ratio of P_e/P_a = 3.5 within the present experimental range.
机译:已经进行了实验研究以检查撞击在平板上的轴对称,膨胀不足的声波射流的传热特性。喷嘴出口压力与环境压力之比,即膨胀不足比在1.5到3.5之间,从喷嘴出口到板的距离在0.5到20.0之间调整。已完成了恢复系数和平板表面压力的详细测量。结果表明,本研究中获得的恢复因子的分布与低速喷射器的分布不同。已经发现,在当前实验范围内,P_e / P_a = 3.5的最大欠膨胀率最高时,停滞点的恢复系数从0.35到超过1.25。