首页> 外文期刊>Journal of Testing and Evaluation >The Effect of Kinematic Viscosity on the Flash Point of Liquids Determined by ASTM D 93 Procedure A, ASTM D 93 Procedure B, and ASTM D 56
【24h】

The Effect of Kinematic Viscosity on the Flash Point of Liquids Determined by ASTM D 93 Procedure A, ASTM D 93 Procedure B, and ASTM D 56

机译:运动粘度对根据ASTM D 93程序A,ASTM D 93程序B和ASTM D 56确定的液体闪点的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The flash point of a liquid material is used to classify whether the material is flammable or combustible. ASTM D 93 is used to determine the flash point of various liquids either by Procedure A or Procedure B. There have been reports of flash point depression when viscous materials were tested using ASTM D 93 Procedure A relative to ASTM D 93 Procedure B. A multi-sample interlaboratory study was conducted to determine the effect of the kinematic viscosity of a liquid material on the observed flsh point when tested according to ASTM D 93 Procedure A relative to the results when tested according to ASTM D 93 Procedure B.
机译:液体材料的闪点用于分类材料是否易燃或可燃。 ASTM D 93用于通过步骤A或步骤B确定各种液体的闪点。有报道称,相对于ASTM D 93程序B,使用ASTM D 93程序A测试粘性材料时,会出现闪点降低的情况。进行了样品间实验室研究,以确定相对于根据ASTM D 93程序B测试时的结果,液体材料的运动粘度对所观察到的肉点的影响。