The air volume of the duct system is important to the performance of the frost-free refrigerator. This paper is focused on the air volume improvement based on the optimization of the duct structure. Firstly, the computational fluid dynamics model of the air duct system in frost-free refrigerator is established, and the grid-independent and validity of the model is investigated according to the experimental data. Secondly, the distribution of velocity, pressure and vortex in fan duct system is studied with the operating conditions, and also the factors of the flow efficiency in duct system are analyzed. Finally, a new air duct system structure is proposed based on the multi-outlet volute and the method of tongue isolation. The results show that the outlet pressure, air volume and air velocity in the new air duct are obviously improved, which means that the new air duct system has a better air supply capability, and it also indicates that the refrigerator has a better cooling effect.
机译:管道系统的空气量对无霜冰箱的性能非常重要。本文的重点是基于管道结构的优化的空气体积改善。首先,建立了无霜冰箱中的空气管道系统的计算流体动力学模型,并根据实验数据研究了型号的网格和有效性。其次,利用操作条件研究了风扇管道系统中的速度,压力和涡流的分布,分析了管道系统中流动效率的因素。最后,基于多出口蜗壳和舌侧隔离方法提出了一种新的风管系统结构。结果表明,新型空气管道中的出口压力,空气量和空气速度明显改善,这意味着新的空气管道系统具有更好的空气供应能力,并且还表明冰箱具有更好的冷却效果。