首页> 外文期刊>Journal of structural fire engineering >Experimental study of post-fire performance of high-strength bolts under combined tension and shear
【24h】

Experimental study of post-fire performance of high-strength bolts under combined tension and shear

机译:高强螺栓组合拉伸和剪切后的射击性能试验研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose - This study aims to verify whether the reduction factors for the post-fire performance of Grade 10.9 bolts stated in an earlier study at the TU Darmstadt are also valid for shear and combined tension and shear. Design/methodology/approach - Tests on Grade 10.9 bolt sets under combined tension and shear were carried out. The tested bolts were heated and cooled without being stressed by an additional mechanical load before being tested. Findings - The test results show that the reduction factors can also be adopted for bolts under combined tension and shear, but the tension-shear-ratio has an influence on the load bearing capacity. Originality/value - The post-fire performance of high-strength bolts is of special interest when a building structure is evaluated after an event of fire. In contrast to conventional structural steel, high-strength bolts do not recover their original strength and material properties.
机译:目的-这项研究旨在验证在达姆施塔特工业大学(TU Darmstadt)较早的一项研究中所述的10.9级螺栓的后燃性能降低因子是否也适用于剪切以及拉伸和剪切组合。设计/方法/方法-对10.9级螺栓组进行了组合拉伸和剪切试验。在测试之前,对被测螺栓进行加热和冷却,而不会受到额外的机械负载的压力。研究结果-试验结果表明,在组合的拉伸和剪切条件下,螺栓也可以采用减缩系数,但是拉伸-剪切比会影响承载能力。原创性/价值-在发生火灾后评估建筑结构时,特别关注高强度螺栓的火灾后性能。与常规结构钢相比,高强度螺栓无法恢复其原始强度和材料性能。