G450 steel to AS 1397 is a cold-reduced sheet steel with in-line galvanizing. Its grade is 450 MPa yield and 480 MPa tensile strength. It is widely used in Australia for purlins, and is being used to fabricate lightweight portal frames, often by welding. The effects of welding on G450 sheet steel in the heat affected zone with respect to the connection strength were unknown. In the present work, transverse and longitudinal fillet, and flare-bevel welded connections in 1.5 and 3.0 mm G450 steel were tested to failure. The test results are used to check the relevant design rules in the North American Specification for Cold-Formed Steel Structural Members and the Australian/New Zealand Standard for Cold-Formed Steel Structures AS/NZS 4600. It was found that the current design rules are not adequate for certain connection configurations in G450 steel to achieve the target safety index of 3.5. Reduced resistance (capacity) factors are proposed for some connections. It was also found that the current design rule for longitudinal flare-bevel welded connections is unnecessarily conservative. The quality of welded connections in thin sheet steels produced by industry fabricators was investigated. The need to complement the macrotest with the destructive prying test as part of the prequalification procedure for such connections is demonstrated. Part of the results of the present work has recently been incorporated into the North American Specification for Cold-Formed Steel Structural Members with a lowering of the thickness to 2.5 mm above which weld throat failure should be checked.
机译:符合AS 1397的G450钢是带直列镀锌的冷轧薄钢板。它的等级是450 MPa屈服强度和480 MPa抗拉强度。它在澳大利亚广泛用于pur条,并且通常用于焊接制造轻型门框。关于热影响区中G450钢板焊接对连接强度的影响尚不清楚。在本工作中,测试了1.5和3.0毫米G450钢的横向和纵向角焊缝以及扩口-斜角焊接连接是否失效。测试结果用于检查北美冷弯钢结构构件规范和澳大利亚/新西兰冷弯钢结构标准AS / NZS 4600的相关设计规则。发现当前的设计规则是对于G450钢中的某些连接配置而言,不足以达到3.5的目标安全指数。对于某些连接,建议降低电阻(容量)因数。还发现,对于纵向扩口-斜角焊接连接的当前设计规则不必要地是保守的。研究了工业制造商生产的薄钢板中焊接连接的质量。证明了需要使用破坏性撬动测试对宏测试进行补充,以作为此类连接的资格预审程序的一部分。当前工作的部分结果最近已被纳入《北美冷弯型钢结构构件规范》,其厚度降低到2.5毫米,超过此厚度应检查焊接喉咙是否损坏。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号