首页> 外文期刊>Journal of structural engineering >Shaking Table Test of a 1:20 Scale High-Rise Building with a Transfer Plate System
【24h】

Shaking Table Test of a 1:20 Scale High-Rise Building with a Transfer Plate System

机译:带有转移板系统的1:20比例高层建筑的振动台测试

获取原文
获取原文并翻译 | 示例
           

摘要

The reinforced concrete building considered in this study has 34 typical floors above a 2.7 m thick transfer plate and a three-level podium. The transfer plate is a reinforced concrete thick plate that transfers the loads from the walls at the typical floors to widely spaced columns in the three-level podium. A microconcrete model representing the high-rise building was constructed in 1:20 scale. Shaking table tests were conducted and the model was subjected to earthquake actions representing minor, moderate, major, and supermajor earthquakes for a region of moderate seismicity, with basic seismic intensity at the VIIth degree pursuant to GB50011-2001. Seismic performance was qualitatively assessed, and it is predicted that the prototype building will not collapse when subjected to major earthquakes. The majority of the damage and failure occurred at the story above the transfer plate. To minimize the damage, it is desirable to strengthen the walls between the 4th and 15th floors as well as reducing any change in stiffness within the transfer plate zone. Data obtained from the shaking table tests were analyzed. Spectral frequencies of the acceleration spectra estimated by the last Fourier transform method and deformation measurements are good indicators on structural damage. Plots of acceleration against displacement would be useful in assessing the locations of structural damage. The use of the ratio of lateral stiffness to check the existence of a soft story may not be appropriate for high-rise buildings. However, story drift relates well with the degree of structural damage.
机译:本研究中考虑的钢筋混凝土建筑在2.7 m厚的转接板和三层裙楼上方有34个典型楼层。转移板是钢筋混凝土厚板,可将载荷从典型楼层的墙壁转移到三层裙楼中的大间距柱子上。以1:20比例构建了代表高层建筑的微混凝土模型。进行了振动台测试,并对模型进行了代表中度地震活动区域的小,中,大和特大地震的地震作用,基本地震烈度为GB50011-2001规定的第七级。对抗震性能进行了定性评估,预计原型建筑物在遭受大地震时不会倒塌。损坏和故障的大部分发生在转移板上方的层上。为了最大程度地减少损坏,希望加强第4层和第15层之间的壁,并减少传递板区域内的刚度变化。分析从振动台测试获得的数据。通过最后的傅立叶变换方法估计的加速度谱的频谱频率和变形测量值是结构损伤的良好指标。针对位移的加速度图将有助于评估结构损坏的位置。使用横向刚度比来检查软层的存在可能不适用于高层建筑。但是,故事漂移与结构破坏的程度密切相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号