首页> 外文期刊>Journal of structural engineering >Structurally Effective Static Wind Loads for Roof Panels
【24h】

Structurally Effective Static Wind Loads for Roof Panels

机译:屋面板的结构有效静态风荷载

获取原文
获取原文并翻译 | 示例

摘要

A detailed comparison of the recent full-scale tests conducted at Mississippi State University (MSU) using simulated wind loads on a portion of a standing seam metal roof and model-scale wind tunnel tests carried out at the University of Western Ontario of an aeroelastic "failure" model of the same roof system is presented. In spite of the significantly different approaches, the results obtained were remarkably consistent. The tests suggest that, at the roof corner, the E1592 uniform pressure test contains conservatism of about 50% for the roof system tested by both approaches; and up to about 80% for the other roof systems tested only at MSU. This conservatism arises if the roof system is required to withstand the code-recommended pressure applied as uniform pressure in the E1592 test, without accounting for the reality of the dynamic spatially varying properties of the wind-induced pressures. In general, the tests also suggest that influence surface approaches together with experimentally measured pressure distributions provide an excellent way of determining the effective loads on various components.
机译:密西西比州立大学(MSU)最近进行的全面测试的详细比较,该测试使用了部分直立金属屋顶的模拟风荷载和在西安大略大学进行的空气动力学模型风洞测试。提出了相同屋顶系统的“故障”模型。尽管采用了截然不同的方法,但获得的结果还是相当一致的。测试表明,在屋顶拐角处,E1592均匀压力测试包含两种方法所测试的屋顶系统的约50%的保守性。仅在MSU进行测试的其他车顶系统最多可达到80%。如果需要屋顶系统承受在E1592测试中作为均匀压力施加的规范建议压力,而又不考虑风压的动态空间变化特性的现实,则会产生这种保守性。通常,这些测试还表明,影响表面的方法以及实验测量的压力分布为确定各种组件的有效载荷提供了一种极好的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号