In dynamic analysis, the energy dissipation in a base-isolated building is typically accounted for by allocating damping properties independently to the superstructure and to the isolation system. Rayleigh damping applied to the superstructure component alone is often used to represent the superstructure energy dissipation. At least one study has indicated that when used improperly, superstructure Rayleigh damping leads to excessive damping of the response of a base-isolated structure. As shown here, even when used as recommended for combining subsystems with disparate damping properties, Rayleigh damping results in undesirable suppression of the first mode response. To correct this behavior, stiffness-proportional damping can be used in lieu of Rayleigh damping. Stiffness-proportional damping is demonstrated to negligibly affect the first mode response, yet provide the expected energy dissipation in higher modes.
机译:在动态分析中,通常通过将阻尼属性独立地分配给上部结构和隔离系统来解决基础隔离建筑物中的能耗问题。单独应用于上部结构部件的瑞利阻尼通常用于表示上部结构的能量耗散。至少一项研究表明,如果使用不当,上层结构的瑞利阻尼会导致对基础隔震结构响应的过度阻尼。如此处所示,即使按建议用于组合具有不同阻尼特性的子系统,瑞利阻尼也会导致对第一模式响应的不良抑制。要纠正此行为,可以使用刚度比例阻尼代替瑞利阻尼。刚度比例阻尼被证明对第一模式响应的影响可忽略不计,但在较高模式下却提供了预期的能量耗散。