The tests were performed on 2.44 m by 2.44 m light-frame wall segments, having oriented strand-board sheathing nailed to sawn lumber framing, to determine their structural response to in-plane and out-of-plane forces applied separately or in combination. There was no evidence that simultaneous application of in-plane and out-of-plane forces negatively affects the strength of walls. However, it was found that interaction of different in-plane force components can substantially reduce strength capabilities of walls relative to when only one in-plane force component exists. Applying both in-plane tension and racking force in the ratio of 1:1 reduced the capacities of walls by 25 to 40%, with how lumber studs are connected to lumber base plates strongly influencing the absolute capacity of any wall.
机译:该测试是在2.44 m x 2.44 m轻型框架墙段上进行的,这些墙段钉有定向的刨花板护套,固定在锯材框架上,以确定它们对分别施加或组合施加的面内和面外力的结构响应。没有证据表明同时施加面内和面外力会对墙体的强度产生负面影响。然而,已经发现,相对于仅存在一个平面内力分量的情况,不同平面内力分量的相互作用可以实质上降低壁的强度能力。以1:1的比例施加平面内拉力和推力时,墙的承载力降低了25%至40%,而木材螺柱与木材底板的连接方式会强烈影响任何墙的绝对承载力。