This paper presents a study that investigated the effectiveness of retrofitting unreinforced masonry infill walls with composite materials to enhance the seismic performance of infilled nonductile RC frames. The primary retrofit scheme considered was the use of engineered cementitious composite overlays. Shake-table tests were conducted on a 2/3-scale, 3-story, 2-bay, masonry infilled RC frame that had one bottom-story wall retrofitted with engineered cementitious composites. The influence of this retrofit on the performance of the structure was investigated using the experimental observations and results of nonlinear finite element analyses. Furthermore, after walls in the second story of the structure were damaged, they were repaired by injecting epoxy into cracked mortar joints, and strengthened with a glass-fiber reinforced polymer overlay. It has been shown that both retrofit schemes are effective in enhancing the seismic performance of the structure and preventing diagonal shear failures of the RC columns.
机译:本文提出了一项研究,研究了用复合材料改造未增强的砖石填充墙以增强填充的非延性RC框架的抗震性能的有效性。所考虑的主要改造方案是使用工程水泥复合材料覆盖层。振动台测试是在2/3比例,3层,2间隔,砖石填充的RC框架上进行的,该框架的一个底层壁已用工程水泥复合材料翻新。通过实验观察和非线性有限元分析的结果,研究了这种改型对结构性能的影响。此外,在结构第二层的墙壁损坏后,通过在破裂的砂浆缝中注入环氧树脂进行修补,并用玻璃纤维增​​强的聚合物覆盖层进行加固。结果表明,两种改造方案均有效地提高了结构的抗震性能,并防止了RC柱的斜向剪切破坏。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号