This paper describes an experimental investigation of steel-sheathed cold-formed steel-framed shear walls by means of dynamic shake table tests. The objective was to evaluate the seismic performance and to identify whether the shear-wall behavior was consistent with past static tests, to obtain measures of damping and natural period of vibration, to investigate the influence of a second story, and to validate and improve the accuracy of the numerically predicted force-deformation response. The scope of study comprised five single-story and five double-story walls of the platform framing technique. Each wall was subjected to a suite of excitations: impact test to measure the linear-viscous damping ratio, harmonic excitation to estimate the natural period of vibration, and ground motions representative of the seismic hazard in Canada. An overview is presented of the test setup and dynamic loading protocols, as well as the test results and numerical model.
机译:本文描述了通过动态振动台试验对带钢护套冷弯型钢框架剪力墙进行的实验研究。目的是评估抗震性能,并确定剪力墙的行为是否与过去的静态测试一致,以获取减震和自然振动周期的度量,调查第二层的影响,并验证和改进数值预测的力-变形响应的精度。研究范围包括平台框架技术的五个单层和五个双层墙。每个墙都受到一系列激励:冲击测试以测量线性-粘滞阻尼比;谐波激励以估计振动的自然周期;以及代表加拿大地震危险的地震动。概述了测试设置和动态加载协议,以及测试结果和数值模型。