This paper presents the seismic performance of two types of cold-formed steel wall systems as characterized during a full-scale five-story building shake table test program: (1) an exterior architectural facade, which spanned the lower three levels of the building, and (2) interior partition wall systems distributed at all levels of the building. The test building was subjected to a suite of earthquake input motions of increasing intensity, first while the building was isolated at its base, and subsequently while it was fixed to the shake table platen. This paper presents the observed physical and measured responses for the two cold-formed steel wall systems and in particular associates physical damage states with measured drift demands in the building. The tests illustrate damage mechanisms for cold-formed steel wall systems when used in architectural facades and highlights areas that should be given particular consideration during seismic design. (C) 2015 American Society of Civil Engineers.
机译:本文介绍了两种冷弯型钢墙系统的抗震性能,这些性能在全面的五层建筑振动台测试程序中得到了体现:(1)覆盖建筑物低三层的外部建筑立面, (2)分布在建筑物各个楼层的内部隔墙系统。首先对测试建筑物进行一系列地震输入运动,首先将其隔离在建筑物的底部,然后将其固定在振动台压板上。本文介绍了两种冷弯型钢墙系统的观测到的物理和测量响应,特别是将物理破坏状态与建筑物中测得的漂移需求相关联。这些测试说明了冷弯型钢墙系统在建筑立面中使用时的损坏机理,并突出了在抗震设计中应特别考虑的区域。 (C)2015年美国土木工程师学会。