Fiber-reinforced resin (FRR) plates are being incorporated into structural joints to correct thermal bridging issues to create more energy-efficient buildings. The purpose of this study was to evaluate the behaviors of simple shear and moment connections that include FRR thermal barrier plates under service-loading conditions. Tests included two thicknesses and two grades of barrier plate. The shear connection tests showed that the coefficient of friction between steel and an as-received FRR plate was significantly lower than that of steel on steel. However, roughening the FRR plates by blasting with aluminum oxide increased the coefficient to nearly the same as or greater than steel on steel. In moment connections the presence of thermal barrier plates increased the joint rotation at the connection. A 25-mm (1-in.) thermal barrier plate increased the joint rotation by 10% compared to a joint without the barrier plate. The increase was 20% for a 50-mm (2-in.) plate. The thermal barrier plates did not affect the dynamic response of the test fixture at structurally important frequencies.
机译:纤维增强树脂(FRR)板被结合到结构接头中,以纠正热桥问题,从而创建更节能的建筑物。这项研究的目的是评估在工作载荷条件下包括FRR热障板的简单剪切和弯矩连接的性能。测试包括两种厚度和两种等级的防护板。剪力连接试验表明,钢与刚收到的FRR板之间的摩擦系数显着低于钢在钢上的摩擦系数。但是,通过用氧化铝喷砂使FRR板变粗糙,可以将系数提高到几乎与钢对钢相同或更高。在瞬间连接中,隔热板的存在增加了连接处的关节旋转。与没有隔板的接头相比,一块25毫米(1英寸)的热障板使接头旋转增加了10%。对于50毫米(2英寸)的印版,增加量为20%。隔热板在结构上重要的频率下不影响测试夹具的动态响应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号