A cyclic loading test was performed to investigate the seismic performance of exterior beam-column joints of concrete-encased-and-filled steel tubular (CEFT) columns. Two specimens with steel beams and two specimens with precast concrete (PC) beams were tested under cyclic loading. The dimensions of the column cross section were 670 x 670 mm, which was a two-thirds-scale model of the prototype column. The test parameters for the steel beam and the PC beam were the beam depth (488 and 588 mm) and the flexural rebar ratio (1.1% and 1.5%), respectively. In the steel beam-CEFT column joints, continuity plates were used, while in the PC beam-CEFT column joints, couplers were used for the rebar connection. The steel beam-column connections failed due to early fracture of the continuity plate, and the PC beam-column connections failed due to rebar buckling and concrete spalling after beam yielding. The strength of the steel beam-column connections was evaluated using an existing design method, and the seismic performance of the PC beam-column connections was evaluated. On the basis of the test results, design considerations for beam-CEFT column joints were recommended. (C) 2015 American Society of Civil Engineers.
机译:进行了循环荷载试验,以研究钢管混凝土(CEFT)柱的外梁柱节点的抗震性能。在循环载荷下测试了两个带有钢梁的标本和两个带有预制混凝土(PC)梁的标本。色谱柱横截面的尺寸为670 x 670 mm,是原型色谱柱的三分之二比例模型。钢梁和PC梁的测试参数分别为梁深度(488和588毫米)和抗弯钢筋比率(1.1%和1.5%)。在钢梁-CEFT柱节点中,使用连续性板,而在PC梁-CEFT柱节点中,使用耦合器进行钢筋连接。钢梁柱连接由于连续板的早期断裂而失败,而PC梁柱连接由于梁屈服后的钢筋屈曲和混凝土剥落而失效。使用现有设计方法评估了钢梁柱连接的强度,并评估了PC梁柱连接的抗震性能。根据测试结果,建议对梁-CEFT立柱节点进行设计考虑。 (C)2015年美国土木工程师学会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号