For the digital control of systems such as grid-connected inverters, measuring inverter output currents accurately is essential. However, current measurement offsets are inevitably generated by current measurement paths and cause DC current components in real inverter output currents. Real inverter output currents with DC components cause the DC-link capacitor voltage to oscillate at the frequency of a utility voltage. For these reasons, current measurement offsets deteriorate the overall system performance. A compensation strategy to eliminate the effect of current measurement offsets in grid-connected inverters is proposed in this study. The validity of the proposed compensation strategy is verified through simulations and experiments. Results show that the proposed compensation strategy improves the performance of grid-connected inverters.
机译:对于数字化系统(如并网逆变器)的数字控制,准确测量逆变器输出电流至关重要。但是,电流测量路径不可避免地会产生电流测量偏移,并且会在实际的逆变器输出电流中引起直流电流分量。具有直流分量的实际逆变器输出电流会导致直流母线电容器电压以市电电压的频率振荡。由于这些原因,电流测量偏移会降低整个系统的性能。本文提出了一种补偿策略,以消除并网逆变器中电流测量失调的影响。通过仿真和实验验证了所提出的补偿策略的有效性。结果表明,所提出的补偿策略提高了并网逆变器的性能。