首页> 外文期刊>Journal of Polymer Research >Cholesterol biosensor based on electrochemically prepared polyaniline conducting polymer film in presence of a nonionic surfactant
【24h】

Cholesterol biosensor based on electrochemically prepared polyaniline conducting polymer film in presence of a nonionic surfactant

机译:在非离子表面活性剂存在下基于电化学制备的聚苯胺导电聚合物膜的胆固醇生物传感器

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Cholesterol biosensor has been fabricated by covalently coupling cholesterol oxidase (ChOx) via glutaraldehyde onto electrochemically prepared polyaniline film in presence of TritonX-100 [4-(1,1,3,3-tetramethylbutyl) phenyl polyethylene glycol], a non-ionic surfactant onto indium-tin-oxide (ITO) glass substrate. These ChOx/PANI-TX-100/ITO bioelectrodes have been characterized using Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV) and scanning electron microscopy (SEM) techniques. The results of response measurements carried out on ChOx/PANI-TX-100/ITO bioelectrodes using amperometric and photometric techniques, reveal detection limit as 5 mg/dl, linearity from 5 to 400 mg/dl of cholesterol and sensitivity as 131 μA/(mg/dl cm?2). These biosensing electrodes are thermally stable up to 65 °C, can be used about 20 times and have a shelf-life of about 10 weeks when stored at 4 °C. Attempts have also been made to utilize the ChOx/PANI-TX-100/ITO bioelectrodes for estimation of free cholesterol concentration in serum samples.
机译:在非离子表面活性剂TritonX-100 [4-(1,1,3,3-四甲基丁基)苯基聚乙二醇]存在下,通过戊二醛将胆固醇氧化酶(ChOx)共价偶联到电化学制备的聚苯胺膜上,从而制造出胆固醇生物传感器。在氧化铟锡(ITO)玻璃基板上。这些ChOx / PANI-TX-100 / ITO生物电极已经使用傅里叶变换红外(FTIR)光谱,循环伏安(CV)和扫描电子显微镜(SEM)技术进行了表征。使用安培法和光度法在ChOx / PANI-TX-100 / ITO生物电极上进行响应测量的结果表明,检测限为5 mg / dl,胆固醇的线性范围为5至400 mg / dl,灵敏度为131μA/( mg / dl cm?2 )。这些生物传感电极在高达65°C的温度下具有热稳定性,可以使用约20次,并且在4°C下存储时的保质期约为10周。也已经尝试利用ChOx / PANI-TX-100 / ITO生物电极来估计血清样品中的游离胆固醇浓度。

著录项

  • 来源
    《Journal of Polymer Research》 |2009年第4期|363-373|共11页
  • 作者单位

    Analytical Chemistry Division North East Institute of Science ampamp Technology Jorhat 785006 Assam India;

    Biomolecular Electronics ampamp Conducting Polymer Research Group National Physical Laboratory Dr K. S. Krishnan Marg New Delhi 110012 India;

    Biomolecular Electronics ampamp Conducting Polymer Research Group National Physical Laboratory Dr K. S. Krishnan Marg New Delhi 110012 India;

    Biomolecular Electronics ampamp Conducting Polymer Research Group National Physical Laboratory Dr K. S. Krishnan Marg New Delhi 110012 India;

    Materials Research Laboratory Department of Chemistry Jamia Millia Islamia New Delhi 110025 India;

    Biomolecular Electronics ampamp Conducting Polymer Research Group National Physical Laboratory Dr K. S. Krishnan Marg New Delhi 110012 India;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Polyaniline; Triton X-100; Cholesterol oxidase; Cholesterol biosensor;

    机译:聚苯胺;Triton X-100;胆固醇氧化酶;胆固醇生物传感器;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号