首页> 外文期刊>日本放射线技术学会杂志 >定量的PET測定に用いる測定器の信頼性: 電離箱式放射能測定装置,ウェル型シンチレーションカウンタ,持続動脈血中放射能濃度測定器およびPET装置の評価
【24h】

定量的PET測定に用いる測定器の信頼性: 電離箱式放射能測定装置,ウェル型シンチレーションカウンタ,持続動脈血中放射能濃度測定器およびPET装置の評価

机译:用于定量PET测量的测量仪器的可靠性:电离室式放射性测量装置,井式闪烁计数器,连续动脉血放射性浓度测量装置和PET装置的评估

获取原文
获取原文并翻译 | 示例
       

摘要

核医学検査の大きな特徴は,体内に投与された 10~(-9)mol程度の放射性薬剤から放出される光子を体外 から動態的に測定し,得られた測定データから局所 的,定量的,非侵襲的に生体内機能を評価すること である.%Purpose: Positron emission tomography (PET) is a powerful tool for measuring in vivo functions such as blood flow, metabolism, enzyme activity, receptors, and transporters. However, plural measuring instruments (i.e., the dose-calibrator, the auto well gamma counter, the continuous blood sampling system) are necessary for the quantitative PET measurement as well as the PET scanner. The purpose of this study was to investigate the reliability of plural measuring instruments from the maintenance data for 6 years. Methods: Four kinds of measuring instrument were evaluated: a dose-calibrator (CAPINTEC, CRC-15R.), an auto well gamma counter (ALOKA, ARC-400), a continuous blood sampling system (ESPEC Techno, PH type), and a dedicated PET scanner (Siemens, ECAT EXACT HR+). We examined whether the initial performance for system sensitivity is maintained. The reliability of the PET scanner was evaluated from the value of mean time between failures (MTBF) for each part of the system obtained from the maintenance data for 6 years. Results: The sensitivity of a dose-calibrator and an auto well gamma counter were maintained virtually constant during the 6 years, but the sensitivity of a continuous blood sampling system was 0.1±3.2% . The sensitivity of a PET scanner was decreased to 92.3% of the initial value. Fifty-one percent of the problems with the PET scanner were for detector block (DB) and analog processor (AP) board. The MTBF of DB and AP board module were 199 and 244 days, respectively. The MTBF of the PET scanner was 56 days. Conclusion: The performance of three measuring instruments, excepting the PET scanner, was relatively stable. The reliability of the PET scanner strongly depends on the MTBF of the DB and AP board. For quantitative PET measurement, it is effective to evaluate the reliability of the system and to make it known to the users.
机译:核医学测试的主要特征是,从人体外部动态测量从体内施用的大约10摩尔摩尔到(-9)摩尔放射性药物发出的光子,并从本地定量获得测量数据,体内功能的非侵入性评估。 %目的:正电子发射断层扫描(PET)是一种功能强大的工具,可用于测量体内功能,例如血流量,新陈代谢,酶活性,受体和转运蛋白。但是,多种测量仪器(例如剂量校准器,自动井伽马定量PET测量和PET扫描仪是必需的)。本研究的目的是从6年的维护数据中研究多种测量仪器的可靠性。方法:四种测量对仪器进行了评估:剂量校准器(CAPINTEC,CRC-15R。),自动井伽玛计数器(ALOKA,ARC-400),连续采血系统(ESPEC Techno,PH型)和专用PET扫描仪(Siemens (ECAT EXACT HR +)。我们检查了系统灵敏度的初始性能是否得以维持。PET扫描仪的可靠性是根据系统各部分的平均故障间隔时间(MTBF)值评估的。结果:在6年中,剂量校准器和自动伽马计数器的灵敏度几乎保持不变,但连续采血系统的灵敏度为0.1±3.2%。 PET扫描仪降至初始值的92.3%.PET扫描仪出现问题的51%是检测器模块(DB)和模拟处理器(AP)板,DB和AP板模块的MTBF分别为199和PET扫描仪的平均无故障时间为244天结论:除PET扫描仪外,其他三种测量仪器的性能都相对稳定。PET扫描仪的可靠性在很大程度上取决于DB和AP板的MTBF。对于定量PET测量,有效的方法是评估系统的可靠性并将其告知用户。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号