Reducing Power Consumption in Data Centers by Jointly Considering VM Placement and Flow Scheduling

机译:结合考虑虚拟机布置和流量调度来降低数据中心的功耗

获取原文
获取原文并翻译 | 示例

摘要

Two important components that consume the majority of IT power in data centers are the servers and the Data Center Network (DCN). Existing works fail to fully utilize power management techniques on the servers and in the DCN at the same time. In this paper, we jointly consider VM placement on servers with scalable frequencies and flow scheduling in the DCN, to minimize the overall system's power consumption. Due to the convex relation between a server's power consumption and its operating frequency, we prove that, given the number of servers to be used, computation workloads should be allocated to severs in a balanced way, to minimize the power consumption on servers. To reduce the power consumption of the DCN, we further consider the flow requirements among the VMs during VM allocation and assignment. Also, after VM placement, flow consolidation is conducted to reduce the number of active switches and ports. We notice that, choosing the minimum number of servers to accommodate the VMs may result in high power consumption on servers, due to servers' increased operating frequencies. Choosing the optimal number of servers purely based on servers' power consumption leads to reduced power consumption on servers, but may increase power consumption of the DCN. We propose to choose the optimal number of servers to be used, based on the overall system's power consumption. Simulations show that, our joint power optimization method helps to reduce the overall power consumption significantly, and outperforms various existing state-of-the-art methods in terms of reducing the overall system's power consumption.
机译:消耗数据中心大部分IT功能的两个重要组件是服务器和数据中心网络(DCN)。现有工作无法同时充分利用服务器和DCN中的电源管理技术。在本文中,我们共同考虑将VM放置在具有可扩展频率的服务器上以及DCN中的流调度,以最大程度地降低整个系统的功耗。由于服务器的功耗与其工作频率之间呈凸形关系,因此我们证明,鉴于要使用的服务器数量,应以均衡的方式分配计算工作负载给服务器,以最大程度地减少服务器的功耗。为了减少DCN的功耗,我们在虚拟机分配和分配期间进一步考虑了虚拟机之间的流量需求。此外,在放置虚拟机之后,将进行流合并以减少活动的交换机和端口的数量。我们注意到,由于服务器的运行频率增加,选择最小数量的服务器以容纳VM可能会导致服务器的高功耗。仅基于服务器的功耗选择最佳服务器数量会减少服务器的功耗,但可能会增加DCN的功耗。我们建议根据整个系统的功耗来选择要使用的最佳服务器数量。仿真表明,我们的联合功率优化方法有助于显着降低总体功耗,并且在降低总体系统功耗方面优于各种现有的最新技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号