Fires involving electrical cables are one of the main hazards in Nuclear Power Plants (NPPs). Cables are complex assemblies including several polymeric parts (insulation, bedding, sheath) constituting fuel sources. This study provides an in-depth characterization of the fire behavior of two halogen-free flame retardant cables used in NPPs using the cone calorimeter. The influence of two key parameters, namely the external heat flux and the spacing between cables, on the cable fire characteristics is especially investigated. The prominent role of the outer sheath material on the ignition and the burning at early times was highlighted. A parameter of utmost importance called transition heat flux, was identified and depends on the composition and the structure of the cable. Below this heat flux, the decomposition is limited and concerns only the sheath. Above it, fire hazard is greatly enhanced because most often non flame retarded insulation part contributes to heat release. The influence of spacing appears complex, and depends on the considered fire property. (C) 2017 Elsevier B.V. All rights reserved.
机译:涉及电缆的火灾是核电厂(NPP)的主要危害之一。电缆是复杂的组件,包括几个构成燃料源的聚合物部件(绝缘,衬垫,护套)。这项研究使用锥形量热仪对NPP中使用的两条无卤阻燃电缆的防火性能进行了深入的表征。特别研究了两个关键参数,即外部热通量和电缆之间的间距,对电缆着火特性的影响。突出了外护套材料在早期点火和燃烧中的重要作用。确定了一个最重要的参数,称为过渡热通量,它取决于电缆的组成和结构。在此热通量以下,分解受到限制,并且仅涉及护套。在此之上,大大提高了火灾隐患,因为大多数情况下,非阻燃绝缘部件会导致热量释放。间距的影响似乎很复杂,并且取决于所考虑的防火特性。 (C)2017 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Journal of Hazardous Materials》 |2018年第15期|306-316|共11页
  • 作者单位

    Ecole Mines Ales, Ctr Mat Mines Ales, Pole Mat Polymeres Avances, 6 Ave Clavieres, F-30319 Ales, France;

    Ecole Mines Ales, Ctr Mat Mines Ales, Pole Mat Polymeres Avances, 6 Ave Clavieres, F-30319 Ales, France;

    IRSN, PSN RES, SA2I, LEF, F-13115 St Paul Les Durance, France;

    IRSN, PSN RES, SA2I, LEF, F-13115 St Paul Les Durance, France;

    Ecole Mines Ales, Ctr Mat Mines Ales, Pole Mat Polymeres Avances, 6 Ave Clavieres, F-30319 Ales, France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Halogen-free flame retardant; Thermally thick behavior; Fire behavior; Cone calorimeter; Cable spacing;

    机译:无卤阻燃剂;热厚性能;防火性能;锥形量热仪;电缆间距;
  • 入库时间 2022-08-17 13:21:45

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号