首页> 外文期刊>Journal of Fusion Energy >Estimation of Excitation Coefficient by Floating Wire Technique for Reflection Magnet of EAST NBI
【24h】

Estimation of Excitation Coefficient by Floating Wire Technique for Reflection Magnet of EAST NBI

机译:EAST NBI反射磁铁的浮线法估算励磁系数

获取原文
获取原文并翻译 | 示例
       

摘要

The principle of floating wire technique is introduced. Wire trace and current are measured through a dipole magnet through 180° in the horizontal plane. Measurements are made for testing the reflection magnet performance of neutral beam injector of experimental advanced superconducting tokamak. The magnetic field intensity is estimated by wire current, wire tension and radius of wire orbit. The excitation coefficient of the reflection magnet is about 1.07, which is in agreement with requirement of engineering design. Using the excitation coefficient, the operation guide data of reflection magnet is given with ion energy, I = 40.99E~(1/2).
机译:介绍了浮线技术的原理。电线走线和电流是通过偶极磁体在水平面内经过180°测量的。进行了测量以测试实验高级超导托卡马克中性束注入器的反射磁体性能。磁场强度由线电流,线张力和线轨道半径估算。反射磁体的激励系数约为1.07,与工程设计要求相符。利用激励系数,以离子能量I = 40.99E〜(1/2)给出反射磁体的工作指导数据。

著录项

  • 来源
    《Journal of Fusion Energy》 |2014年第2期|166-170|共5页
  • 作者单位

    Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China;

    Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China;

    Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China;

    Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Neutral beam injection; Reflection magnet; Floating wire;

    机译:中性束注入;反射磁铁;浮线;