首页> 外文期刊>Journal of Fire Sciences >How could the fire fatalities have been prevented? An analysis of 144 cases during 2011-2014 in Sweden: An analysis
【24h】

How could the fire fatalities have been prevented? An analysis of 144 cases during 2011-2014 in Sweden: An analysis

机译:如何避免火灾死亡?瑞典2011-2014年144例病例分析:分析

获取原文
获取原文并翻译 | 示例
           

摘要

Approximately 80%-90% of all fire-related fatalities take place in residential occupancies. The risk groups are well known, but the effectiveness of different measures has been less investigated. In this article, fire investigations from 144 unintentional fatal residential fires have been systematically analyzed and technical measures that would have been effective in preventing each fatality have been identified. The result shows that, generally, a thermally activated suppression system (e.g. sprinkler) has the highest potential effectiveness (68%) followed by a detector-activated system in bedroom and living room (59%) or smoke alarm (37%). For smokers with home care, however, the potential effectiveness of a thermally activated suppression system and home smoke alarm was significantly lower (31% and 14%, respectively). This indicates that different measures are effective for different groups. In one-fifth of the cases, the victim could have evacuated but chose not to do so, primarily to attempt to extinguish the fire.
机译:在所有与火灾有关的死亡中,约有80%-90%发生在居住场所。风险人群是众所周知的,但是对不同措施的有效性的研究较少。在本文中,已对144起意外致命住宅火灾的火灾调查进行了系统地分析,并确定了可以有效防止每种死亡的技术措施。结果表明,通常,热激活抑制系统(例如洒水喷头)具有最高的潜在效率(68%),其次是卧室和起居室中的探测器激活系统(59%)或烟雾报警器(37%)。但是,对于有家庭护理的吸烟者,热激活抑制系统和家庭烟雾报警器的潜在效果明显较低(分别为31%和14%)。这表明不同的措施对不同的群体有效。在五分之一的案件中,受害者本可以撤离,但选择不撤离,主要是为了扑灭大火。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号