首页> 外文期刊>Journal of Environmental Science and Health, Part B: Pesticides, Food Contaminants, and Agricultural Wastes >Analysis of antibiotic fungicide kasugamycin in irrigation water by high performance liquid chromatography
【24h】

Analysis of antibiotic fungicide kasugamycin in irrigation water by high performance liquid chromatography

机译:高效液相色谱法分析灌溉水中抗生素杀菌剂春日霉素

获取原文
获取原文并翻译 | 示例
       

摘要

A high performance liquid chromatographic (HPLC) analysis method with an ultraviolet (UV) detector and an Aqua C18 (250 × 4.6 mm, Phenomenex) column were applied to analyze the antibiotic fungicide kasugamycin in water. An aromatic sulfonic acid spe column (Backerbond, J. T. Backer) was used to remove the interfering materials from irrigation water. A good linear relation existed between the concentration of the fungicide and the peak area, and correlation coefficient of linearity from 0.1 to 10.2 μg/mL was 0.998. The accuracies expressed as the recoveries of kasugamycin from irrigation water ranged from 112.2 to 111.7 %. The precisions expressed as relative standard deviations (RSD) were found to be below 7.0 %. The quantitative detection limit (LOQ) of kasugamycin in irrigation water was set at 2.2 μg/mL which was 2-times higher than the method detection limit (MDL) 1.03 μg/mL. Electrospray ionization-mass (ESI-MS) and fast-atom bombardment-mass (FAB-MS) were applied to compare the ability of identifying the component of the eluent peak from HPLC, and the result indicated that electrospray ionization-mass (ESI-MS) was more sensitive than fast-atom bombardment-mass (FAB-MS) in the detection of kasugamycin. There was no kasugamycin residue detected in irrigation water samples collected from paddyfields at Wufong, indicated that the residues of kasugamycin in water were less than 2.2 μg/mL, and the risk of water contamination was very low.
机译:高效液相色谱(HPLC)分析方法与紫外线(UV)检测器和Aqua C18(250×4.6 mm,Phenomenex)色谱柱应用于分析水中的抗生素杀菌剂春日霉素。使用芳族磺酸柱(Backerbond,J.T.Backer)从灌溉水中除去干扰物质。杀菌剂的浓度和峰面积之间存在良好的线性关系,线性相关系数从0.1到10.2μg/ mL为0.998。从灌溉水中回收的春日霉素的准确度范围为112.2%至111.7%。发现以相对标准偏差(RSD)表示的精度低于7.0%。灌溉水中春黄霉素的定量检出限(LOQ)设置为2.2μg/ mL,比方法检出限(MDL)1.03μg/ mL高2倍。应用电喷雾电离质量(ESI-MS)和快速原子轰击质量(FAB-MS)来比较HPLC鉴定洗脱液峰成分的能力,结果表明电喷雾电离质量(ESI- MS在检测春黄霉素方面比快速原子轰击质谱(FAB-MS)更为灵敏。从五丰水田收集的灌溉水样品中没有检测到春黄霉素残留,表明水中的春黄霉素残留量小于2.2μg/ mL,水污染的风险非常低。

著录项

  • 来源
  • 作者

  • 作者单位

    Department of Applied Chemistry, Chaoyang University of Technology, Taiwan;

    Taiwan Agricultural Chemicals and Toxic Substances Research Institute, Council of Agriculture, Taiwan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 00:57:56