首页> 外文期刊>Journal of Environmental Science and Health, Part B: Pesticides, Food Contaminants, and Agricultural Wastes >Determination of sixteen pesticides in peppers using high-performance liquid chromatography/mass spectrometry
【24h】

Determination of sixteen pesticides in peppers using high-performance liquid chromatography/mass spectrometry

机译:高效液相色谱/质谱法测定辣椒中的十六种农药

获取原文
获取原文并翻译 | 示例
       

摘要

A method for the detection and quantification of 16 pesticides: flufenoxuron, fenoxycarb, dimethomorph, acetamiprid, imidacloprid, lufenuron, thiacloprid, thiabendazole, thiophanate-methyl, spinosad, fenbutatin oxide, methoxyfenozide, oxamyl, clothianidin, thiamethoxam and carbendazim has been developed based on high-performance liquid chromatography-mass spectrometry. Pesticide residues were extracted from the samples according to the QuEChERS method which stands for quick, esay, cheap, effective, rugged and safe. Homogenised analytical portions (10 g ± 0.1) of samples of peppers were spiked at two levels (10 and 100 μg Kg−1) with a small volume of an appropriate standard mixture solution containing each pesticide. Analyses were performed using electrospray ionization (ESI) and a MSD trap system. Chromatography separation was achieved using a ZORBAX SB-C18 3.5 μm particle size analytical column, 2.1 × 50 mm from Agilent, with gradient elution at a flow-rate of 0.4 mL/min with mobile phases: waters-0.1 % HCOOH-5 mM HCOONH4 and MeOH-5 mM HCOONH4. The method has been validated based on the SANCO European Guidelines. Under the optimized conditions the recoveries (n = 7) were in the range 70-110 % with satisfactory precision (CV ≤ 20 %). A linear dynamic range was obtained over a range of concentrations from 10 to 100 μg Kg−1 for each of the analytes, with correlation coefficients >0.997.
机译:一种检测和定量16种农药的方法:氟虫草隆,苯氧威,灭虫灵,扑热息痛,吡虫啉,氟苯脲酮,噻虫啉,噻苯达唑,甲基托布津,多杀菌素,芬非他汀,氧化甲氧基苯甲酰肼,草酰戊基,可比灭威和已开发的噻虫草胺高效液相色谱-质谱联用。根据QuEChERS方法从样品中提取农药残留,代表了快速,简便,便宜,有效,坚固耐用和安全的特点。将胡椒样品的均质分析部分(10 g±0.1)加标成两种水平(10和100μgKg -1> sup>),并加入少量每种农药的适当标准混合溶液。使用电喷雾电离(ESI)和MSD捕集阱系统进行分析。使用ZORBAX SB-C18 3.5 µm粒径分析柱,从安捷伦获得2.1×50 mm色谱柱,流动相以0.4 mL / min的流速进行梯度洗脱,实现水相分离:waters-0.1%HCOOH-5 mM HCOONH 4 和MeOH-5 mM HCOONH 4 。该方法已根据SANCO欧洲指南进行了验证。在优化的条件下,回收率(n = 7)处于70-110%的范围内,具有令人满意的精度(CV≥20%)。线性动态范围是在浓度范围从10到100μgKg -1 的每种分析物,相关系数> 0.997。

著录项

  • 来源
  • 作者

  • 作者单位

    Instrumental Laboratory, Technological National Center of Canning Industry (CTC), Murcia, Spain;

    Dept. Agricultural Chemistry, Geology and Pedology, University of Murcia, Murcia, Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 00:57:58

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号