首页> 外文期刊>Journal of electrical and computer engineering >Analysis of Transient Voltage Stability in a Low Voltage Distribution Network Using SST for the Integration of Distributed Generations
【24h】

Analysis of Transient Voltage Stability in a Low Voltage Distribution Network Using SST for the Integration of Distributed Generations

机译:使用SST集成分布式发电的低压配电网中的暂态电压稳定性分析

获取原文
获取原文并翻译 | 示例
       

摘要

Models of a low voltage distribution network using a typical tertiary-structure solid state transformer (SST) for the integration of distributed generations (DGs) and a conventional low voltage distribution network integrated with DGs were established to study the transient voltage stability issue, using the power system simulation software PSCAD. Effects on the transient voltage stability of the load bus and DC bus in the SST system are analyzed when grid-side cable line faults (such as short circuit and line disconnection) occur or the total output of DGs drops greatly. The results show that, comparing with the conventional system, the SST has apparent advantages on enhancing the transient voltage stability of load bus while facing different disturbances, even though SST has to regulate the voltage passively. Short circuit faults at different location of the grid-side line have different effects on the transient voltage stability, while the effect of disconnection fault is not related to fault location. Moreover, the DC bus voltage is easy to keep climbing continually when short circuit fault of the line occurs that is close to the SST input stage or disconnection fault occurs at any location of the line. If a battery energy storage station is installed, the transient voltage stability of DC bus and load bus will be improved effectively because of the regulation function of battery storage.
机译:建立了使用典型的三次结构固态变压器(SST)进行分布式发电(DG)集成的低压配电网和集成了DGs的常规低压配电网的模型,以研究瞬态电压稳定性问题。电力系统仿真软件PSCAD。当发生电网侧电缆线路故障(例如短路和断线)或DG的总输出大幅下降时,分析了SST系统中负载总线和DC总线对瞬态电压稳定性的影响。结果表明,与传统系统相比,尽管SST必须被动调节电压,但SST在面对不同干扰的情况下仍具有增强负载母线瞬态电压稳定性的明显优势。电网侧线路不同位置的短路故障对瞬态电压稳定性的影响不同,而断线故障的影响与故障位置无关。此外,当发生靠近SST输入级的线路短路故障或线路的任何位置发生断线故障时,直流母线电压很容易连续不断攀升。如果安装了蓄电池储能站,则由于蓄电池的调节功能,可以有效地改善直流母线和负载母线的暂态电压稳定性。

著录项

  • 来源
    《Journal of electrical and computer engineering》 |2018年第1期|3498491.1-3498491.9|共9页
  • 作者单位

    School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China;

    School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China;

    School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China;

    School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 03:54:51

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号