首页> 外文期刊>Journal of Constructional Steel Research >Flexural strength experiments on exterior metal building wall assemblies with rigid insulation
【24h】

Flexural strength experiments on exterior metal building wall assemblies with rigid insulation

机译:具有刚性绝缘的金属外墙建筑组件的抗弯强度试验

获取原文
获取原文并翻译 | 示例
           

摘要

This research program evaluated the flexural capacity of a metal building wall system with rigid board foam insulation sandwiched between C- and Z-section girts and through-fastened steel panels. Vacuum box tests were conducted to simulate wind suction on the wall system, and distinct failure modes were observed. The metal panel pulled over the screw heads for wall systems without insulation, however when rigid board insulation was added, the insulation acted as a washer and girt failure or screw fracture was observed. Screw bending and fracture were common in the specimens with the thickest rigid board insulation and for locally stocky cross-sections because a concentrated moment could be developed in the fastener. In these cases wall system capacity was decreased by the presence of rigid board insulation. For wall system specimens with locally slender girts, rigid board insulation did not influence girt capacity because girt deformation under load was primarily in the cross-section and not at the through-fastened connections.
机译:该研究程序评估了夹在C型截面和Z型截面梁和贯通固定式钢板之间的,带有硬质板泡沫保温材料的金属建筑墙体系统的挠曲能力。进行了真空箱测试,以模拟墙面系统上的风吸力,并观察到了不同的失效模式。金属面板将墙壁系统的螺钉头拉到没有绝缘层的位置,但是当添加刚性板绝缘层时,绝缘层起到了垫圈的作用,并且观察到了钉扎故障或螺钉断裂。螺钉弯曲和断裂在具有最厚刚性板绝缘层和局部局部横截面的样品中很常见,因为在紧固件中会产生集中力矩。在这些情况下,墙板系统的容量由于存在刚性板绝缘而降低。对于墙体局部细长的墙体系统,刚性板绝热不会影响墙体的承载能力,因为墙体在荷载作用下的变形主要是在横截面上,而不是在贯通连接处。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号