首页> 外文期刊>Journal of Constructional Steel Research >Static and seismic experiment for bolted-welded joint in modularized prefabricated steel structure
【24h】

Static and seismic experiment for bolted-welded joint in modularized prefabricated steel structure

机译:模块化预制钢结构螺栓焊接缝的静,抗震试验

获取原文
获取原文并翻译 | 示例
           

摘要

This study proposes a type of bolted-welded beam-column joint for modularized prefabricated multi-rise and high-rise steel structures. The components in the same module are welded in the factory, and the modules are quickly assembled using the proposed joint at site. The static performance, hysteretic performance, skeleton curves, ductile performance, energy dissipation capacity, rotation capacity and stiffness degradation patterns of four joints are obtained by model experiment and finite element analyses, and the effect of thicknesses of the chords and web members on the static and seismic performance of the joint as well as the effect of welding quality are investigated. The results show that due to the presence of the bolted connecting parts, the proposed joints maintain relatively good seismic performance including ductile performance, energy dissipation capacity and plastic rotation capacity, and good static bearing capacity after the welding seams fracture, so they can be used in structures of seismic zones. Reducing the thicknesses of the chord and the web members can significantly decrease the load-bearing capacity of the joint; however, this decrease is not proportional to the decrease of the cross-sectional area. In addition, reducing the thicknesses of the chord and web members has no significant impact on the ductile performance and energy dissipation capacity of the joint. Simplified computation formulas for load-bearing capacity of the joint were proposed and the computation results get along well with the experimental results. (C) 2015 Elsevier Ltd. All rights reserved.
机译:本研究提出了一种用于模块化预制多层高层和高层钢结构的螺栓焊接梁柱节点。同一模块中的组件在工厂进行了焊接,然后使用现场建议的接头快速组装模块。通过模型实验和有限元分析,获得了四个接头的静态性能,滞后性能,骨架曲线,延性性能,能量耗散能力,旋转能力和刚度退化模式,以及弦和腹板厚度对静力的影响。研究了接头的抗震性能以及焊接质量的影响。结果表明,由于螺栓连接件的存在,所提出的接头在延展性,能量耗散能力和塑性旋转能力方面具有相对较好的抗震性能,并且在焊缝断裂后具有良好的静态承载力,因此可以使用。在地震带的结构中。减小弦和腹板的厚度可显着降低接头的承重能力;但是,这种减小与横截面积的减小不成比例。另外,减小弦和腹板构件的厚度对接头的延展性能和能量耗散能力没有显着影响。提出了简化的节点承载力计算公式,计算结果与实验结果吻合较好。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Journal of Constructional Steel Research》 |2015年第12期|417-433|共17页
  • 作者单位

    Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China;

    Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China;

    Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China;

    Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China;

    Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China;

    Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China;

    Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Prefabricated steel structure; Bolted-welded truss-column joint; Static performance; Seismic capacity; Experimental study; Simplified calculation;

    机译:预制钢结构;焊接桁架-柱节点;静力性能;抗震性能;试验研究;简化计算;