首页> 外文期刊>Journal of Constructional Steel Research >Limitations on the use of partial shear connection in composite beams with steel T-sections and uniformly spaced rib shear connectors
【24h】

Limitations on the use of partial shear connection in composite beams with steel T-sections and uniformly spaced rib shear connectors

机译:在钢制T型截面和均布肋骨剪力连接器的组合梁中使用局部剪力连接的限制

获取原文
获取原文并翻译 | 示例
           

摘要

Design codes like EC4 allow the bending resistance of composite beams with partial shear connection (PSC) to be assessed by plastic analysis procedures, based on equilibrium of forces across the composite section (equilibrium method). However, these plastic design models are limited to connectors, usually shear studs, with sufficient deformation capacity (at least 6 mm) and composite beams, where the steel sections have either equal flanges or only slightly differing areas of top and bottom flange. Beyond that, EC 4 defines a minimum degree of shear connection to be provided, that was derived for composite members with double flange steel section and stud connectors through systematic FE analysis. For composite beams with steel T-section (without top flange) and uniformly spaced rib shear connectors, limitations on the use of partial shear connection have not yet been investigated. Due to significant discrepancies in terms of steel section geometry and ductility of the connectors a simple adoption of regulations from EC4 is not possible and presumably unsafe. To resolve that problem, the paper presents the results of numerical simulations, based on which limitations on the use of partial shear connection have been derived for beams with steel T-sections and uniformly spaced connectors. (C) 2017 Elsevier Ltd. All rights reserved.
机译:像EC4这样的设计规范允许通过塑性分析程序,基于跨复合截面的力平衡(平衡法),来评估具有部分剪力连接(PSC)的复合梁的抗弯强度。但是,这些塑料设计模型仅限于连接器,通常是具有足够变形能力(至少6毫米)的抗剪螺柱和复合梁,其中钢截面的法兰相等,或者顶部和底部法兰的面积仅稍有不同。除此之外,EC 4定义了要提供的最小剪切连接度,这是通过系统有限元分析为具有双法兰钢截面和双头螺栓连接器的复合构件得出的。对于具有钢制T形截面(无顶部翼缘)和均匀间隔的肋骨剪力连接器的复合梁,尚未研究使用部分剪力连接的限制。由于在连接器的钢截面几何形状和延展性方面存在重大差异,因此无法简单地采用EC4的规定,并且可能不安全。为了解决该问题,本文提出了数值模拟的结果,在此基础上,对钢T形截面和均等间距连接器的梁,得出了部分剪力连接的使用限制。 (C)2017 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Journal of Constructional Steel Research》 |2018年第3期|99-112|共14页
  • 作者

    Classen Martin;

  • 作者单位

    Rhein Westfal TH Aachen, Inst Struct Concrete, Mies van der Rohe Str 1, D-52074 Aachen, Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);