首页> 外文期刊>Journal of building performance simulation >Model validation study of carbon monoxide transport due to portable electric generator operation in an attached garage
【24h】

Model validation study of carbon monoxide transport due to portable electric generator operation in an attached garage

机译:附带车库中便携式发电机运行引起的一氧化碳运输模型验证研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A series of tests was conducted to characterize the indoor carbon monoxide (CO) concentrations resulting from portable electric generators operating in the attached garage of a test house under various use and environmental conditions. An extensive model validation effort using the multizone airflow and indoor air quality (IAQ) model CONTAM was carried out using the data from seven tests with a generator operating in the attached garage to compare predicted CO concentrations with measured values. The agreement between the measurements and predictions of the O-2 concentrations in the garage and the average CO concentration for the house zones was excellent for the data set as a whole. The agreement was somewhat worse for the garage CO concentrations. Overall, the house zone average and garage CO concentration predictions and measurements were within about 20% and 30%, respectively, when averaged over all cases.