Summer thermal comfort: compliance assessment and overheating prevention in new apartment buildings in Estonia

机译:夏季热舒适度:爱沙尼亚新公寓楼的合规评估和过热预防

获取原文
获取原文并翻译 | 示例
           

摘要

This study analyses which building parameters contribute the most to overheating in dwellings and which properties will make a room critical', to be chosen for compliance assessment procedure through temperature simulation, as required in Estonia for new residential buildings. Indoor temperature measurements, conducted in 18 apartments from 16 apartment buildings, show clear evidence of overheating. Compliance assessment of 25 new buildings were conducted using IDA-ICE software. The analysed sample consisted of typical multi-storeyed buildings with mainly massive concrete structures. From the simulated buildings, 68% did not meet the requirements, showing that this relatively new building code requirement was not fully established in practice. Results of the analysis indicate that the requirement in apartment buildings is achievable without cooling, if passive measures are properly applied. Recommendations are given to designers, as well as policy-makers, to improve the situation in the residential building sector.
机译:这项研究分析了哪些建筑参数对住宅过热的影响最大,哪些属性将使房间变得至关重要”,这将根据爱沙尼亚在新住宅建筑中的要求,通过温度模拟进行选择,以进行符合性评估程序。在16栋公寓楼中的18栋公寓中进行的室内温度测量显示了明显的过热迹象。使用IDA-ICE软件对25座新建筑物进行了符合性评估。分析的样本由典型的多层建筑组成,主要是大型混凝土结构。在模拟建筑物中,有68%的建筑不符合要求,这表明相对较新的建筑法规要求在实践中并未完全确立。分析结果表明,如果适当采用被动措施,则无需冷却即可达到公寓楼的要求。建议设计者和决策者改善住宅建筑领域的状况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号