The brightness of single‐crystal cathodes of LaB6 oriented in the 〈100〉, 〈110〉, and 〈111〉 directions and six other random directions has been measured. The 〈111〉 cathodes produced currents and brightnesses significantly lower than all other orientations. The other orientations studied produced maximum brightnesses in the range 0.7–1.0 MA/cm2 sr, although the 〈100〉 orientation consistently produced currents higher than other orientations and brightnesses as high or higher than most orientations. A change in impurity level from 1540 ppm to less than 1 ppm had no statistical effect on brightness for crystals of the same orientation.
机译:测量了沿B100〈,〈110〉和and111〉方向以及其他六个随机方向取向的LaB6单晶阴极的亮度。 〈111〉阴极产生的电流和亮度明显低于所有其他方向。研究的其他方向产生的最大亮度在0.7-1.0 MA / cm2 sr范围内,尽管〉100〉方向始终产生比其他方向更高的电流,并且亮度高于或高于大多数方向。对于相同取向的晶体,杂质含量从1540 ppm到小于1 ppm的变化对亮度没有统计影响。