首页> 外文期刊>Journal of Applied Physics >Detection of x rays from the anode of a vacuum arc
【24h】

Detection of x rays from the anode of a vacuum arc

机译:检测来自真空电弧阳极的X射线

获取原文

摘要

A vacuum arc with hollow cylindrical anode can generate an arc voltage in excess of 10 000 V with currents in excess of 1000 A. A model has been developed that describes this high arc voltage as being caused by the conduction of the current through an electron space‐charge region near the anode. The detection of x rays emitted from the anode at the time of the high arc voltage has confirmed the model of this vacuum arc. An x‐ray pinhole camera gave spatial resolution and showed that the x rays were emitted from the anode. A p‐i‐n diode x‐ray detector gave temporal resolution and showed that the x rays were emitted during the high arc voltage mode. A lithium fluoride crystal spectrometer gave energy resolution and showed that the emitted x rays were characteristic of the copper anode. This experiment confirmed that the major energy dissipation mechanism for this arc during the high voltage mode was the bombardment of the anode by electrons.
机译:具有空心圆柱形阳极的真空电弧可以在电流超过1000 A的情况下产生超过10 000 V的电弧电压。已经开发出了一个模型,该模型描述了这种高电弧电压是由电流通过电子空间传导引起的靠近阳极的充电区域。在高电弧电压时从阳极发射的X射线的检测已经证实了这种真空电弧的模型。 X射线针孔照相机给出了空间分辨率,并显示X射线是从阳极发出的。一个p-i-n二极管x射线检测器提供了时间分辨率,并显示了x射线是在高电弧电压模式下发射的。氟化锂晶体光谱仪给出了能量分辨率,并表明发出的X射线是铜阳极的特征。该实验证实,在高压模式下,该电弧的主要能量耗散机制是电子对阳极的轰击。

著录项

  • 来源
    《Journal of Applied Physics 》 |1982年第4期| P.2975-2982| 共8页
  • 作者

  • 作者单位
  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号