首页> 外文期刊>Journal of Applied Physics >Nonlinear analysis of a permanent magnet synchronous machine with nonsinusoidal stator winding currents
【24h】

Nonlinear analysis of a permanent magnet synchronous machine with nonsinusoidal stator winding currents

机译:具有非正弦定子绕组电流的永磁同步电机的非线性分析

获取原文
           

摘要

Permanent magnet synchronous machines and induction motors are often required to operate on‐line starting or inverter‐fed systems, which results in nonsinusoidal stator currents. These, in turn, give rise to undesirable harmonics and power losses which degrade motor performance. In this paper a time‐domain analysis is presented for evaluating the magnetic field distribution in the two‐dimensional cross section of the machine under load conditions. The analysis is applied to a permanent magnet synchronous machine under locked rotor conditions. Although for purposes of this analysis, the iron permeability has been assumed a constant, the method can be easily extended to include iron saturation.
机译:在线启动或逆变器供电系统通常需要永磁同步电机和感应电动机,这会导致非正弦定子电流。这些反过来会引起不良的谐波和功率损耗,从而降低电机性能。本文提出了一种时域分析方法,用于评估负载条件下机器二维截面中的磁场分布。该分析适用于转子锁定状态下的永磁同步电机。尽管出于分析目的,铁渗透率假定为常数,但该方法可以轻松扩展为包括铁饱和度。