Characterization of noise sources in a microfabricated single-beam zero-field optically-pumped magnetometer

机译:微耦合的单光束零场光学泵浦磁力计中噪声源的表征

获取原文
获取原文并翻译 | 示例
           

摘要

We present an experimental noise characterization of a miniature single-beam absorption-based optically-pumped magnetometer with a noise floor of 7fT/Hz(1/2) operating in the spin-exchange relaxation-free regime. We experimentally evaluate noise arising from the laser intensity, laser frequency, laser polarization, cell temperature, and magnetic field coils used for the phase-sensitive detection of the magnetometer signal. We find that noise in the range between DC and 30Hz is a result of noise sources coupling to the atoms in a manner similar to a magnetic field, while the noise at frequencies above 30Hz is mainly due to laser intensity noise. Our results place an upper limit on the noise sources for our system that matches well with the noise spectrum of the magnetometer at frequencies above 5Hz.
机译:我们介绍了基于微型单梁吸收的光学泵浦磁力仪的实验噪声表征,其中7英尺/ Hz(1/2)的噪声底板在自旋交换松弛状态下操作。我们通过实验评估来自激光强度,激光频率,激光偏振,电池温度和用于磁力计信号的相位敏感检测的磁场线圈引起的噪声。我们发现DC和30Hz之间的范围内的噪声是以类似于磁场的方式耦合到原子的噪声源的结果,而高于30Hz的频率的噪声主要是由于激光强度噪声。我们的结果对我们系统的噪声源的噪声源极限相匹配,其磁力计在5Hz以上的频率下匹配。

著录项

  • 来源
    《Journal of Applied Physics》 |2019年第4期|044504.1-044504.7|共7页
  • 作者单位

    Univ Colorado Boulder CO 80309 USA;

    Univ Colorado Boulder CO 80309 USA;

    Univ Colorado Boulder CO 80309 USA;

    Univ Colorado Boulder CO 80309 USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号