...
首页> 外文期刊>Journal of Applied Physics >Birefringence Changes During Retraction of Oriented Polystyrene Monofilaments. I. Changes of Average Birefringence
【24h】

Birefringence Changes During Retraction of Oriented Polystyrene Monofilaments. I. Changes of Average Birefringence

机译:定向聚苯乙烯单丝缩回期间的双折射变化。一,平均双折射的变化

获取原文
获取原文并翻译 | 示例

摘要

The changes in average birefringence during retraction have been measured at 85°C for four different oriented polystyrene monofilaments. The relationship between birefringence decay and length decrease is not linear: the birefringence decay is relatively more rapid than the length decrease, in all cases. Also, the birefringence‐length relationship seems to be essentially independent of retraction temperature. Birefringence decay rate can be reduced by a factor of 1000 by not allowing the filament to retract. One of the filaments shows an interesting change in sign of the birefringence, from negative to positive, in the final stages of the retraction. The birefringence decay data for the four filaments could not be reduced to any universal curve by plotting either birefringence or relative birefringence against any simple functions of length or extension (all the filaments were made from the same polymer, so that a reduction to some such common basis should be possible). Analyzing the data in terms of a distribution of retardation times, by assuming that birefringence decay and length decrease are in some constant ratio for each retardation time (where the additional parameter, time, is introduced), also failed to reduce the data to a single common curve. Internal stress may be an essential parameter for a proper characterization of the birefringence.
机译:对于四种不同的取向的聚苯乙烯单丝,在85℃下测量了收缩期间平均双折射的变化。双折射衰减与长度减小之间的关系不是线性的:在所有情况下,双折射衰减都比长度减小相对更快。同样,双折射长度关系似乎基本上与回缩温度无关。通过不允许灯丝缩回,双折射衰减率可以降低1000倍。在回缩的最后阶段,一根细丝显示出双折射符号的有趣变化,从负到正。通过将双折射或相对双折射相对于长度或延伸的任何简单函数作图,无法将这四根丝的双折射衰减数据简化为任何通用曲线(所有丝均由相同的聚合物制成,因此可以简化为一些这样的通用基础应该是可能的)。通过假设双折射衰减和长度减小在每个延迟时间(引入了附加参数time)的某个恒定比率下,根据延迟时间的分布来分析数据,也未能将数据缩减为一个共同曲线。内部应力可能是正确表征双折射的重要参数。

著录项

  • 来源
    《Journal of Applied Physics 》 |1956年第9期| 共6页
  • 作者

    Andrews R. D.; Rudd J. F.;

  • 作者单位

    Physical Research Laboratory, The Dow Chemical Company, Midland, Michigan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号