This study investigated the effect of equilibration tem- perature on PM10 concentrations from the tapered element oscillating microbalance (TEOM) method by operating collocated TEOM monitors at different equilibration tem- peratures in an airshed (the Lower Fraser Valley, British Columbia). This airshed contained an abundance of par- ticulate semivolatile material (PSVM). For the period when three collocated TEOM monitors were operated, the PM10 from the monitor at an equilibration temperature of 30 deg. C was 2.5 mu g/m3 (22) and 1.7 (17) mu g/m3 higher, on average, than the PM10 from monitors at 50 and 40 deg. C, respectively, and the differences were proportional to the ambient PM10 loading. Greater volatilization of PSVM in the TEOM monitors at higher equilibration temperatures may have been a cause of the differences.
机译:这项研究通过在流域(不列颠哥伦比亚省下弗雷泽谷地)不同平衡温度下操作并置的TEOM监测器,研究了锥形元件振荡微量天平(TEOM)方法对平衡温度对PM10浓度的影响。空域中包含大量的颗粒状半挥发性物质(PSVM)。在运行三台并置的TEOM监测器期间,监测器中的PM10处于30度的平衡温度下。 C在50和40度时平均比监测仪中的PM10高2.5μg / m3(22)和1.7(17)g g / m3。分别为C和差,它们与PM10的环境负荷成正比。在较高的平衡温度下,TEOM监视器中PSVM的更大挥发可能是造成差异的原因。