首页> 外文期刊>Journal of the air & waste management association >Comparison of current Federal Reference Methods for ambient lead measurements adjacent to a secondary lead smelter
【24h】

Comparison of current Federal Reference Methods for ambient lead measurements adjacent to a secondary lead smelter

机译:电流联邦参考方法对辅助铅冶炼厂附近的环境铅测量的比较

获取原文
获取原文并翻译 | 示例
           

摘要

The United States Environmental Protection Agency (EPA) reduced their National Ambient Air Quality Standard (NAAQS) for lead (Pb) an order of magnitude to a concentration level of 0.15 micrograms per cubic meter (mu g/m(3)) when the new rule was promulgated in 2008. At that time, the possibility of revising the Pb sampling method from total suspended particulate (TSP) to particulate matter less than or equal to 10 mu m in diameter (PM10) was considered due to potential measurement bias of the Pb-TSP monitoring technique. The New York State Department of Environmental Conservation (NYSDEC) has been operating source-orientated colocated TSP and PM10 monitors documenting ambient air lead (Pb) concentrations since 2011 at a site adjacent to a secondary Pb smelter in Wallkill, New York. The colocated Wallkill data show a very strong correlation between the readings recorded by these two sampling techniques. After the range of the variability in the individual Pb-PM10/Pb-TSP ratios was reduced by using a 0.005 mu g/m(3) concentration cut point, because of the concerns about the measurements at low concentrations, an adjustment factor (AF) of 1.49 was calculated using the remaining data set. This AF can be used to estimate Pb-TSP concentrations from Pb-PM10 readings at this Wallkill source-orientated location. It was stated by the EPA that there is only a limited data set in situations where Pb-TSP and Pb-PM10 are colocated, especially for those sites considered to be source-oriented, so the analyses performed and summarized herein for the Wallkill colocated airborne Pb concentration data add to that limited data set. Implications: These data analyses add to the limited data set in situations where Pb-TSP and Pb-PM10 are colocated to help refine the derivation of a site-specific adjustment factor for estimating TSP Pb concentrations from measured PM10 Pb concentrations. This could assist the EPA in transitioning away from the use of the Pb-TSP monitoring technique, with its indicated measurement bias, for the Pb NAAQS to the use of Pb-PM10 instead. An adjustment factor of 1.49 was calculated that could be used to estimate Pb-TSP concentrations from Pb-PM10 values collected around this source-orientated location.
机译:美国环境保护局(EPA)将其国家环境空气质量标准(NAAQS)降低到铅(PB)的级别为0.15微克/立方米的浓度水平(MU G / M(3))根据此时,由于潜在的测量偏差,考虑了统治,在此时,考虑将Pb采样方法从总悬浮颗粒(TSP)重新定义为小于或等于10μm的颗粒物质(PM10)的可能性。 PB-TSP监控技术。纽约国家环境保护部(NYSDEC)一直经营源自源头的CONECATED TSP和PM10监视器,以自2011年在纽约WALLKILL的二级PB冶炼厂毗邻的网站。 Coolocated Wallkill数据显示了这两种采样技术记录的读数之间的非常强烈的相关性。通过使用0.005μg/ m(3)浓度切割点降低了各个PB-PM10 / PB-TSP比率的可变性范围,因为关于在低浓度下测量的担忧,调整因子(AF )使用剩余的数据集计算1.49。该AF可用于估计该壁板源代码位置的PB-PM10读数的PB-TSP浓度。 EPA中所说的是,在PB-TSP和PB-PM10被共同定位的情况下只有有限的数据,特别是对于所考虑的源导向的那些站点,因此在此进行并总结在此用于壁板CONCONATED空气传播的分析PB浓度数据添加到该有限数据集。含义:这些数据分析添加到位于PB-TSP和PB-PM10的情况下集合的有限数据,以帮助改进特定于特定于特定的调整因子的推导,以估计来自测量的PM10 PB浓度的TSP PB浓度。这可以帮助EPA转换使用PB-TSP监测技术的使用,其指示的测量偏差,用于使用PB-PM10的PB NAAQ。计算调整因子为1.49,可以用于估计周围收集的PB-PM10值的PB-TSP浓度。

著录项

  • 来源
  • 作者单位

    New York State Dept Environm Conservat Div Air Resources 625 Broadway Albany NY 12233 USA;

    New York State Dept Environm Conservat Div Air Resources 625 Broadway Albany NY 12233 USA;

    New York State Dept Environm Conservat Div Air Resources 625 Broadway Albany NY 12233 USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号